HOMEPAGE  
Pro HD/4K Cameras

The Marshall CV346 offers Full-HD resolution in 1920x1080p at up to 60 fps in a sturdy, durable form factor, and straightforward design. The CV346 is suitable for use in Full-HD broadcast and Pro AV workflows including live broadcast productions, sportscast, newscast, reality television, concerts, corporate, government, courtroom, house of worship and many more.


Marshall CV346

Compact HD Camera (3GSDI & HDMI)

Owner's Manual Camera Tips and Tricks Specsheet Download Firmware Update Instructions Download Firmware Upload Tool Download Latest Firmware Download Camera Control Software Visca Command List Hirose 12-pin Connector Pinout Download Images

  • HDMI & 3G/HDSDI output
  • 2.5 Megapixel (1/2.8") sensor (4:2:2 color)
  • Interchangeable CS/C lens mount (sold separately)
  • Full-HD resolutions: 1920 x 1080p, 1920 x 1080i, and 1280 x 720p
  • Frame rates: 60, 59.94, 50, 30, 29.97, 25, 24, 23.98 fps
  • Remote adjust through RS485 (Visca) or OSD menu joystick
  • Audio Line input does not provide power to the audio device. Mic will use Mic Bias 1.7V and up to 3mA max current
  • Wide range of picture adjustment settings including paint (red/blue), white balance, gain control, pedestal (blacks), white clip, exposure, gamma, and more
  • Includes 12v power supply, can operate 12V+/-10% with a 6 watt draw

Rear view of CV346 compact full-HD Camera with 3G/HDSDI/HDMI
CV346 camera rear view
The Marshall CV346 Full-HD Miniature Camera offers performance, flexibility, and value in a compact form factor. Built around a next generation 2.5-Megapixel, 1/2.8-inch sensor, the CV346 delivers ultra-crisp, clear progressive Full-HD video up to 1920x1080p at 60/59/50fps and interlaced 1920x1080i at 60/59/50fps.

The CV346 utilizes a full-sized HDMI and BNC (3G/HDSDI) output on rear panel and locking I/O connection for power, control, and stereo audio input (embedded on HDMI & 3G/HDSDI outputs). The CV346's CS lens mount offers a wide range of prime and varifocal lens options from ultra-wide to telephoto.

The CV346 can capture detailed shots while maintaining an ultra-discreet compact point-of-view perspective without sacrificing versatility or convenience. Remote adjustment and picture settings commands are delivered via common RS485 (Visca) or OSD menu joystick on locking breakout cable. A wide range of picture adjustment settings are available and adjustable from a distance including paint (red/blue), white balance, exposure, gain control, pedestal (blacks), white clip, gamma, and more.

Hirose Breakout Cable (included with camera)

Hirose Breakout Cable
  • 1. RS-485 wire (+/-) Input
  • 2. 12V Power 2.1 mm Plug (Center Contact)
  • 3. Hirose connector plugs into camera
  • 4. OSD Menu Control
  • 5. TRS Audio Mic/Line-level input


CV346 applications:

The CV346 is suitable for use in HDMI Pro AV workflows or HDSDI environments including live broadcast productions, courtroom capture, corporate video, government assembly, sportscast, newscast, reality television, concerts, house of worship and many more.

Touchscreen RCP Camera Control

CV-RCP-V2

Touchscreen RCP Camera Control
Remote adjust & match cameras via RS485

Read more
Mini Camera Stands and Mounts accessories

1/4"-20 Mounts

1/4"-20 Compact Camera Stands & Mounts,
Clamps, Articulating arms and more...

Read more
Compact Weatherproof Camera Housing with Fan and Heater

CV-H20-HF

Compact Weatherproof Camera Housing with Fan & Heater

Read more
10 feet Hirose Breakout Cable

CV-BSE-10FT

10 foot (3.05m) Hirose Breakout Replacement Cable for
CV Series Cameras

Read more
Original 2 ft. Hirose Breakout Replacement Cable

CV-BSE-CBLE

Original 2 ft. Hirose Breakout Replacement Cable



Read moreClick to Buy
Touchscreen RCP Camera Control

CV-USB-RS485

USB to RS485/422 Adapter for use with Marshall Windows Camera Control Software.

Call for Price

CV-PT-HEAD Micro Pan and Tilt Head

CV-PT-HEAD

Micro Pan/Tilt Head

Read more

Click Here For Additional Accessories

Lens Options for CV344, CV346, CV366, CV368 cameras

CS mount Varifocal Manual Focus Lens options for CV344, CV346, CV366, CV368
  Part No. Mount Type Megapixel Rating Focal Length Horizontal AOV Iris F-Stop M.O.D.
CS mount 3MP Varifocal Lens VS-M2812-4MP CS Mount 4MP 2.8~12mm 110°~25° DC Auto (4 pin) F1.4~close 0.3m
CS mount 3MP Varifocal Lens VS-M550-5 CS Mount 3MP 5~50mm 55°~6° DC Auto
(4 pin)
F1.4 0.3m
CS mount 3MP Varifocal Lens VS-M660 CS Mount 3MP 6~60mm 50°~5° DC Auto
(4 pin)
F1.4 0.3m
CS2810MP 10MP CS mount focal length Iris F-stop focus range CS2810MP CS Mount 10MP 2.8mm 101.4° Manual F1.6 0.3m
CS1150-8MP 8MP CS mount focal length Iris F-stop focus range CS1150-8MP CS Mount 8MP 11~50mm 45°~10°approx DC Auto (4 pin) F1.4~close 0.8m
C1670-8MP 8MP CS mount focal length Iris F-stop focus range C1670-8MP C Mount 8MP 16~70mm 30°~7°approx DC Auto (4 pin) F1.4~close 0.8m
CS-3.2-12MP CS-3.2-12MP CS 12MP 3.2mm 131° Fixed F2.0 0.3m~∞


Fixed Prime (CS mount) Lens options for CV344, CV343, CV346, CV345, CV365, CV366, CV368
  Part No. Megapixel Rating Focal Length Horizontal AOV F-Stop M.O.D.
Fixed Prime CS mount lens V-555.0-5MP-VIS-IR 1/2 5MP 5.0mm 63° (1/3"), 75.5° (1/2.5"), 98° (1/1.7") F2.0 0.8m - ∞
Fixed Prime CS mount lens V-557.6-5MP-VIS-IR 1/2 5MP 7.6mm 40.4° (1/3"), 48° (1/2.5"), 60° (1/1.7") F2.0 1.5m - ∞


 

Camera Control Application

  1. Download Camera Control Software HERE
  2. Use USB to RS485/RS422 Converter (CV-USB-RS485)
  3. Use cat5 or 24AWG twisted-pair wire (sold separately)
  4. Connect cable from RS485(+) terminal on Camera to T/R (+) on USB/RS485 converter
  5. Connect cable from RS485(-) terminal on Camera to T/R (-) on USB/RS485 converter
  6. Plug USB cable from USB/RS485 converter into USB port on Laptop or Computer (note ComPort#)
  7. Open up CamControl Program and match Serial Port to corresponding ComPort# used
  8. Select Baudrate in CamControl Program and match it in Camera OSD Menu under DISPLAY CONTROL > BAUDRATE
  9. Select Camera Address in CamControl Program and match it in Camera OSD Menu under DISPLAY CONTROL > CAM ID
  10. Select Open in CamControl Program
  11. Test connection by pushing MENU in lower right of CamControl Program - OSD Menu should come up on video signal
  12. Commands can also be sent without using OSD Menu
Camera Control Software display



* Pricing does not reflect freight costs and applicable taxes and duties
* Pricing, specification and features are subject to change

COMPANY INFO

Trade Shows | Press Releases | Company Logos | About Us | Private Policy

WHERE TO BUY

Broadcast/AV Dealers | Broadcast/AV Intl. Distributors | GSA Dealers | Optical Intl. Distributors | Optical US Distributors

PRODUCT RESOURCES

RMA Request | Warranty | Software & Firmware | Catalogs | Discontinued Products | Overstock & Closeouts

BRANDS


MARSHALL MXL MOGAMI TAJIMI